Integrated System for Accurate Electrical Measurement Monitoring

Muchtar, Taufik and Utami, Atikah Tri Budi and Lutfi, Lutfi and Gani, Hamdan (2024) Integrated System for Accurate Electrical Measurement Monitoring. Journal of Engineering Research and Reports, 26 (2). pp. 51-59. ISSN 2582-2926

[thumbnail of Muchtar2622024JERR111834.pdf] Text
Muchtar2622024JERR111834.pdf - Published Version

Download (626kB)

Abstract

Aims: This study aims to develop an integrated system for accurate electrical measurement monitoring.

Study Design: The acquisition embedded system is developed using research and development study.

Place and Duration of Study: Department of Machinery Automation System, Polytechnic ATI. Makassar, Indonesia, between March 2021 and October 2021.

Methodology: The performance of the proposed integrated acquisition embedded system and conventional measurement is compared through different testing.

Results: The results showed that the device worked as expected and was right on target. The device test error is compared with direct measurement with the measuring instrument; the voltage error is 0.17%, the current error is 0.46%, the power error is 0.89%, and the frequency error is 0.01%. System devices can measure and monitor several electricity measurements.

Conclusion: The experimental results show that the system can function correctly. The integrated acquisition system can operate with great accuracy. This study is expected to contribute to establishing a system that will benefit the government's efforts to preserve energy efficiency.