Accuracy of non-contrast CT brain interpretation by emergency physicians: A cohort study

Khan, Anas and Qashqari, Sami and Al-Ali, Abdul-Aziz (2013) Accuracy of non-contrast CT brain interpretation by emergency physicians: A cohort study. Pakistan Journal of Medical Sciences, 29 (2). ISSN 1681-715X

[thumbnail of 3220-13807-1-PB.pdf] Text
3220-13807-1-PB.pdf - Published Version

Download (1MB)

Abstract

Objective: To assess the accuracy of emergency physicians (EPs) in the interpretation of non-contrast CT Brain (NCCT Brain) by examining the inter rater reliability between EPs and radiology specialists.

Methodology: A four months prospective cohort study was conducted at emergency department of King Khalid University Hospital (KKUH), Riyadh, Saudi Arabia. We studied the daily performance of our EPs, and compared it to the radiological report issued within the week after. Data were analyzed by calculating sensitivity, specificity, accuracy and agreement (kappa statistic), using radiology report as the reference standard.

Results: Out of 241 cases eligible for the study, 210 (87.14%) were concordant, and 31 (12.86%) were discordant. The agreement (kappa) was to be 0.64.

Conclusion: We concluded that our EPs are moderately accurate at interpreting NCCT Brain studies. Further education and training programs were necessary for all our EPs to improve the accuracy. Further studies are required to determine the most cost-effective method of minimizing consequential misinterpretations.

Item Type: Article
Subjects: Institute Archives > Medical Science
Depositing User: Managing Editor
Date Deposited: 17 May 2023 04:13
Last Modified: 02 Jan 2024 12:44
URI: http://eprint.subtopublish.com/id/eprint/2281

Actions (login required)

View Item
View Item