Shear-Wave Elastography Variability Analysis and Relation with Kidney Allograft Dysfunction: A Single-Center Study

Bolboacă, Sorana D. and Elec, Florin Ioan and Elec, Alina Daciana and Muntean, Adriana Milena and Socaciu, Mihai Adrian and Iacob, Gheorghita and Zaro, Răzvan and Andrieș, Alexandra-Ioana and Bădulescu, Ramona Maria and Ignat, Radu Mihai and Iancu, Mihaela and Badea, Radu Ion (2020) Shear-Wave Elastography Variability Analysis and Relation with Kidney Allograft Dysfunction: A Single-Center Study. Diagnostics, 10 (1). p. 41. ISSN 2075-4418

[thumbnail of diagnostics-10-00041-v2.pdf] Text
diagnostics-10-00041-v2.pdf - Published Version

Download (2MB)

Abstract

Shear-wave elastography (SWE) showed the absence or presence of significant differences among stable kidney allograft function and allograft dysfunction. We evaluated the variability of kidney allograft stiffness in relation to allograft dysfunction, respectively, in terms of a correlation of stiffness with patients’ characteristics. A single-center prospective study on patients who had undergone renal transplantation was conducted between October 2017 and November 2018. Patients were clinically classified as having a stable allograft function or allograft dysfunction. SWE examinations performed by the same radiologist with a LOGIQ E9 were evaluated. Ten measurements were done for Young’s modulus (kPa) at the level of allograft cortex and another ten at the level of medulla. Eighty-three SWE examinations from 63 patients, 69 stable allografts, and 14 allografts with dysfunction were included in the analysis. The intra-examinations stiffness showed high variability, with the quantile covariation coefficient ranging from 2.21% to 45.04%. The inter-examinations stiffness showed heterogeneity (from 28.66% to 42.38%). The kidney allograft cortex stiffness showed significantly higher values in cases with dysfunction (median = 28.70 kPa, interquartile range (IQR) = (25.68–31.98) kPa) as compared to those with stable function (median = 20.99 kPa, interquartile range = (16.08–27.68) kPa; p-value = 0.0142). Allograft tissue stiffness (both cortex and medulla) was significantly negatively correlated with body mass index (−0.44, p-value < 0.0001 for allograft cortex and −0.42, p-value = 0.0001 for allograft medulla), and positively correlated with Proteinuria/Creatinuria ratio (0.33, p-value = 0.0021 for allograft cortex and 0.28, p-value = 0.0105 for allograft medulla) but remained statistically significant only in cases with stable function. The cortical tissue stiffness proved significantly higher values for patients with allograft dysfunction as compared to patients with stable function, but to evolve as an additional tool for the evaluation of patients with a kidney transplant and to change the clinical practice, more extensive studies are needed.

Item Type: Article
Subjects: Institute Archives > Medical Science
Depositing User: Managing Editor
Date Deposited: 23 Jan 2023 05:18
Last Modified: 16 Sep 2023 04:12
URI: http://eprint.subtopublish.com/id/eprint/1464

Actions (login required)

View Item
View Item