A validated, related substance, GC method for 1,4-cyclohexanedione mono-ethylene Ketal

Karthikeyan, B. and Srinivasan, V. (2010) A validated, related substance, GC method for 1,4-cyclohexanedione mono-ethylene Ketal. Journal of Biophysical Chemistry, 01 (01). pp. 72-75. ISSN 2153-036X

[thumbnail of JBPC20100100009_37338657.pdf] Text
JBPC20100100009_37338657.pdf - Published Version

Download (900kB)

Abstract

ABSTRACT A simple, economic, and time-efficient related substance, GC method has been developed for the analysis of 1,4-Cyclohexanedione mono- ethylene ketal(will be specified as ketal) in the presence of a potential impurity 1,4-cyclohexa- nedione bis (ethylene ketal) [will be specified as diketal]. Successful chromatographic separa- tion of the ketal from the impurity was achieved on a DBWAX ETR, 30 m x 0.32 mm x 1.0μ FT column with nitrogen as carrier gas and FID detector. The method was validated for linearity, accuracy, precision, and specificity and can be used for quality control during manufacture of ketal. A validated GC method is reported for the ketal for the first time.

Item Type: Article
Subjects: Institute Archives > Chemical Science
Depositing User: Managing Editor
Date Deposited: 18 Mar 2023 06:56
Last Modified: 01 Jan 2024 12:28
URI: http://eprint.subtopublish.com/id/eprint/1223